测试设备DUT状态
DUT带壳,未安装导电泡棉
-
辐射抗扰度试验
辐射抗扰度试验,270MHz频段出现画面卡死,试验暂停未继续。
-
BCI试验
CBCI出现故障
- RE试验
30~200M H方向
Frequency (MHz) |
MaxPeak (dBμV/m) |
Average (dBμV/m) |
Limit (dBμV/m) |
Margin (dB) |
Meas. Time (ms) |
Bandwidth (kHz) |
Pol |
Corr. (dB) |
72.000000 |
29.60 |
— |
34.00 |
4.40 |
— |
— |
H |
-23.8 |
77.150000 |
— |
28.15 |
21.00 |
-7.15 |
— |
— |
H |
-23.6 |
82.250000 |
32.94 |
— |
41.00 |
8.06 |
— |
— |
H |
-23.3 |
82.300000 |
— |
31.08 |
21.00 |
-10.08 |
— |
— |
H |
-23.3 |
92.500000 |
35.02 |
— |
44.00 |
8.98 |
— |
— |
H |
-22.7 |
92.550000 |
— |
32.97 |
24.00 |
-8.97 |
— |
— |
H |
-22.7 |
102.900000 |
— |
42.47 |
24.00 |
-18.47 |
— |
— |
H |
-21.5 |
102.900000 |
44.47 |
— |
44.00 |
-0.47 |
— |
— |
H |
-21.5 |
108.000000 |
— |
30.26 |
24.00 |
-6.26 |
— |
— |
H |
-21.0 |
169.800000 |
— |
30.44 |
21.00 |
-9.44 |
— |
— |
H |
-18.6 |
169.850000 |
34.42 |
— |
41.00 |
6.58 |
— |
— |
H |
-18.6 |
179.950000 |
28.85 |
— |
32.00 |
3.15 |
— |
— |
H |
-18.6 |
30~200M V方向
Frequency (MHz) |
MaxPeak (dBμV/m) |
Average (dBμV/m) |
Limit (dBμV/m) |
Margin (dB) |
Meas. Time (ms) |
Bandwidth (kHz) |
Pol |
Corr. (dB) |
66.750000 |
30.07 |
— |
34.00 |
3.93 |
— |
— |
V |
-23.8 |
71.900000 |
36.52 |
— |
34.00 |
-2.52 |
— |
— |
V |
-23.8 |
71.900000 |
— |
35.23 |
24.00 |
-11.23 |
— |
— |
V |
-23.8 |
77.050000 |
37.76 |
— |
41.00 |
3.24 |
— |
— |
V |
-23.6 |
77.050000 |
— |
36.74 |
21.00 |
-15.74 |
— |
— |
V |
-23.6 |
82.100000 |
37.71 |
— |
41.00 |
3.29 |
— |
— |
V |
-23.4 |
82.150000 |
— |
36.28 |
21.00 |
-15.28 |
— |
— |
V |
-23.3 |
87.300000 |
— |
36.86 |
24.00 |
-12.86 |
— |
— |
V |
-23.1 |
92.400000 |
44.62 |
— |
44.00 |
-0.62 |
— |
— |
V |
-22.8 |
92.450000 |
— |
42.99 |
24.00 |
-18.99 |
— |
— |
V |
-22.8 |
102.800000 |
45.83 |
— |
44.00 |
-1.83 |
— |
— |
V |
-21.5 |
102.800000 |
— |
43.63 |
24.00 |
-19.63 |
— |
— |
V |
-21.5 |
- 结果分析
5.1 BCI试验
试验中主要有两个问题,1是摄像头的抗干扰能力弱,2是DUT在绝缘垫上未可靠接地,在经过换摄像头之后通过; 换摄像头是IMS摄像头为样件,新摄像头为量产项目IMS摄像头,上面RE试验结果是新摄像头
5.2 RI试验在换摄像头后未测试;
5.3
RE试验目前主要有两个频段存在问题,1是30~200频段,存在频率间隔为5.15MHz左右的规律性尖峰,根据经验,这种应为数据信号类的干扰,电源信号引起可能不大;根据基频5.15推测,最大可能为板卡25MHz时钟应用的数据接口模块问题,目前已找到最大可能性的,有一根SOC25MHz时钟,因为与晶振采用防呆设计,导致该时钟在信号末端由0Ω电阻处断开无负载,走线也很长,可能性非常大,已找软件关闭该时钟。
20210616更新
上面网口的5.15MHz左右的脉冲,经过优化优化车载以太网的layout后已经消失
加上对比
以上两张图,是对比两版硬件版本的效果,优化了车载以太网layout
大电流注入BCI试验,视频卡死问题
主要是与一级电源的共膜电感参考地有关。
原设计是将共模电感后的地,DGND与机壳安装孔用0欧电阻连接,共膜电感前的地,不做处理,通过电源回线作为回路。
新的整改方案是,将共模电感前的地,通过0欧电阻与机壳安装孔连接起来,相当于共模电感前后的地均接到机壳安装孔,机壳为金属外壳,测试时通过接地线可靠接到测试铜板上。
此操作解决BCI以及CE电流法超标的问题。
原设计时会超标
整改后
可以通过试验
此整改方案仍未搞清楚干扰信号的回流路径 共模电感在上电时的工作状态 后续研究下