MCE
Error Diagnose: DIMMxxx memory fault is doubted of
this error.
Error Handling Suggestion: Please shut down system and check this DIMM and its slot carefully.
Change its slot and power on system again.
If the error still occurs on this DIMM, the fault cause is identified.
Replace it with a new one.
xxx表示内存丝印编号
Error Diagnose: SLOTN card doubled as source of this
error.
Error Handling Suggestion:Please shut down system and check this card and its slot carefully.
Change its slot and power on system again.
If the error still occurs on this card, the fault cause is identified.
Replace it with a new one.
N表示PCIe槽位号
Error Diagnose: CPUN fault is doubted as source of
this error.
Error Handling Suggestion:Please shut down system and check this CPU and its socket carefully.
Change its socket and power on system again.
If the IERR still occurs on this CPU, the fault cause is identified.
Replace it with a new one.
N表示CPU编号
Error Diagnose: It should be soft error.
Error Handling
Suggestion: Reset system, If no error could be replicated, the error
should be considered as soft error, no more action need to be taken.
–
IERR
Error Diagnose: CPUN Power fault is doubted as source
of this IERR.
Error Handling Suggestion: Please shut down system and check the power, VR and its relative
devices carefully.
Exchange power or backplane and power on system again.
Measure its voltage at run time. If the IERR still occurs on this
device, the fault cause is identified. Replace it with a new one.
N表示CPU编号
Error Diagnose: DIMMxxx memory fault is doubted as
source of this IERR.
Error Handling Suggestion: Please shut down system and check this DIMM and its slot carefully.
Change its slot and power on system again.
If the IERR still occurs on this DIMM, the fault cause is identified.
Replace it with a new one.
xxx表示内存丝印编号
Error Diagnose: CPUN fault is doubted as source of
this IERR.
Error Handling Suggestion:Please shut down system and check this CPU and its socket carefully.
Change its socket and power on system again.
If the IERR still occurs on this CPU, the fault cause is identified.
Replace it with a new one.
N表示CPU编号
Error Diagnose: SLOTN card fault is doubted as source
of this 3-Strike error.
Error Handling Suggestion: Please shut down system and check this card and its slot carefully.
Change its slot and power on system again.
If the error still occurs on this card, the fault cause is identified.
Replace it with a new one.
N表示PCIe槽位号
Error Diagnose: DIMMxxx memory fault is doubted as
source of this 3-Strike error.
Error Handling Suggestion:Please shut down system and check this DIMM and its slot carefully.
Change its slot and power on system again.
If the error still occurs on this DIMM, the fault cause is identified.
Replace it with a new one.
xxx表示内存丝印编号
Error Diagnose: Sorry, Don't isolate source of this IERR.
Error Handling Suggestion: Reset system and try to replicate this
IERR, Detect whether this IERR is followed with some device or concur
with some special operation action. And copy this error data to Huawei
technical service engineer for deep analysis.
–