NAND FLASH命名规则

2023-05-16

基于网络的一个修订版

三星的pure nandflash(就是不带其他模块只是nandflash存储芯片)的命名规则如下:

1.Memory(K)
2. NANDFlash: 9
3. Small Classification
(SLC : Single Level Cell, MLC : Multi Level Cell,
SM : SmartMedia, S/B : Small Block)
1 : SLC 1 Chip XD Card
2 : SLC 2 Chip XD Card
4 : SLC 4 Chip XD Card
A : SLC + Muxed I/ F Chip
B : Muxed I/ F Chip
D : SLC Dual SM
E : SLC DUAL (S/ B)
F : SLC Normal
G : MLC Normal
H : MLC QDP
J : Non-Muxed OneNand
K : SLC Die Stack
L : MLC DDP
M : MLC DSP
N : SLC DSP
Q : 4CHIP SM
R : SLC 4DIE STACK (S/ B)
S : SLC Single SM
T : SLC SINGLE (S/ B)
U : 2 STACK MSP
V : 4 STACK MSP
W : SLC 4 Die Stack
4~5. Density
12 : 512M
16 : 16M
28 : 128M
32 : 32M
40 : 4M
56 : 256M
64 : 64M
80 : 8M
1G : 1G
2G : 2G
4G : 4G
8G : 8G
AG : 16G
BG : 32G
CG : 64G
DG : 128G
00 : NONE
6~7. organization
00 : NONE
08 : x8
16 : x16
8. Vcc
A : 1.65V~3.6V
B : 2.7V (2.5V~2.9V)
C : 5.0V (4.5V~5.5V)
D : 2.65V (2.4V ~ 2.9V)
E : 2.3V~3.6V
R : 1.8V (1.65V~1.95V)
Q : 1.8V (1.7V ~ 1.95V)
T : 2.4V~3.0V
U : 2.7V~3.6V
V : 3.3V (3.0V~3.6V)
W : 2.7V~5.5V, 3.0V~5.5V
0 : NONE
9. Mode
0 : Normal
1 : Dual nCE & Dual R/ nB
4 : Quad nCE & Single R/ nB
5 : Quad nCE & Quad R/ nB
9 : 1st block OTP
A : Mask Option 1
L : Low grade
10. Generation
M : 1st Generation
A : 2nd Generation
B : 3rd Generation
C : 4th Generation
D : 5th Generation
11. "—"
12. Package
A : COB
B : TBGA
C : CHIP BIZ
D : 63-TBGA
E : TSOP1 (Lead-Free, 1217)
F : WSOP (Lead-Free)
G : FBGA
H : TBGA (Lead-Free)
I : ULGA (Lead-Free)
J : FBGA (Lead-Free)
K : TSOP1 (1217)
L : LGA
M : TLGA
N : TLGA2
P : TSOP1 (Lead-Free)
Q : TSOP2 (Lead-Free)
R : TSOP2-R
S : SMART MEDIA
T : TSOP2
U : COB (MMC)
V : WSOP
W : WAFER
Y : TSOP1
13. Temp
C : Commercial
I : Industrial
S : SmartMedia
B : SmartMedia BLUE
0 : NONE (Containing Wafer, CHIP, BIZ, Exception
handling code)
3 : Wafer Level 3
14. Bad Block
A : Apple Bad Block
B : Include Bad Block
D : Daisychain Sample
K : Sandisk Bin
L : 1~5 Bad Block
N : ini. 0 blk, add. 10 blk
S : All Good Block
0 : NONE (Containing Wafer, CHIP, BIZ, Exception
handling code)
15. NAND-Reserved
0 : Reserved
16. Packing Type
- Common to all products, except of Mask ROM
- Divided into TAPE & REEL(In Mask ROM, divided into TRAY, AMMO Packing Separately)


Hynix

H 2 7 X X X X X X X X X - X X
(1) HYNIX
(2) PRODUCT FAMILY
(4) POWER SUPPLY(VCC)
(8) NAND CLASSIFICATION
(7) ORGANIZATION
(14) BAD BLOCK
(11) PACKAGE TYPE
2 :Flash
S: SLC + Single Die + Small Block
A: SLC + Double Die + Small Block
B: SLC + Quadruple Die + Small Block
F: SLC + Single Die + Large Block
G: SLC + Double Die + Large Block
H: SLC + Quadruple Die + Large Block
J: SLC + ODP + Large Block
K: SLC + DSP + Large Block
T: MLC + Single Die + Large Block
U: MLC + Double Die + Large Block
V: MLC + Quadruple Die + Large Block
W: MLC + DSP + Large Block
Y: MLC + ODP + Large Block

C
E
M
I
B
S
P
: 1~5 Bad Block Included
: Included Bad Block
: All Good Block


T: TSOP1
V: WSOP
S: USOP
N: LSOP1
F: FBGA
X: LGA
M: WLGA
Y: VLGA
U: ULGA
W: Wafer
C: PGD1 (chip)
K: KGD
D: PGD2

: 1st
: 2nd
: 3rd
: 4th
M
A
B
C
(5), (6) DENSITY
1: 1 nCE & 1 R/nB; Sequential Row Read Enable
2: 1 nCE & 1 R/nB; Sequential Row Read Disable
4: 2 nCE & 2 R/nB; Sequential Row Read Enable
5: 2 nCE & 2 R/nB; Sequential Row Read Disable
D: Dual Interface; Sequential Row Read Disable
F: 4 nCE & 4 R/nB ; Sequential Row Read Disable

micron镁光nand命名规则

www.micron.com/support/designsupport/documents/png

Standard NANDFlashPart Numbering System
Micron's part numbering system is available at
Standard NANDFlash*
MT 29F 2G 08 A A A WP - xx xx xx xx ES : A
Micron Technology Design Revision (shrink)
A = 1st design revision
Single-SupplyFlash
29F = Single-Supply NANDFlashProduction Status
29H = High Speed NAND Blank = Production
ES = Engineering samples
Density QS = Qualification samples
1G = 1Gb MS = Mechanical samples
2G = 2Gb
4G = 4Gb Operating Temperature Range
8G = 8Gb Blank = Commercial (0°C to +70°C)
16G = 16Gb ET = Extended (–40°C to +85°C)
32G = 32Gb WT = Wireless (–25°C to +85°C)
64G = 64Gb
128G = 128Gb Block Option (Reserved for use)
256G = 256Gb Blank = Standard device
Device WidthFlashPerformance
08 = 8 bits Blank = Full specification
16 = 16 bits
Speed Grade (MT29H Only)
Classification 15 = 133 MT/s
12 = 166 MT/s
Mark Bit/cell Die RnB
A SLC 1 1 Package Code
B SLC 2 1 WP = 48-pin TSOP I (CPL version) (Pb-free)
C SLC 2 1 WC = 48-pin TSOP I (OCPL version) (Pb-free)
D SLC 2 2 H1 = 100-ball VFBGA (Pb-free), 12 x 18 x 1.0
E SLC 2 2 H2 = 100-ball TFBGA (Pb-free), 12 x 18 x 1.2
F SLC 4 2 HC = 63-ball VFBGA, 10.5 x 13 x 1.0
G SLC 4 2 C2 = 52-pad ULGA, 12 x 17 x 0.4 (use TBD)
J SLC 4 + 4 2 + 2 C3 = 52-pad ULGA, 12 x 17 x 0.65
K SLC 8 4 C4 = 52-pad VLGA, 12 x 17 x 1.0 (SDP/DDP/QDP)
Z SLC 1 NA C5 = 52-pad VLGA, 14 x 18 x 1.0 (SDP/DDP/QDP)
C6 = 52-pad LLGA, 14 x 18 x 1.47 (8DP, QDP, DDP)
M MLC 1 1 C7 = 48-pad LLGA, 12 x 20 x 1.47 (8DP)
N MLC 2 1 SWC = 48-pin Stacked TSOP (OCPL version) (Pb-free)
P MLC 2 1 SWP = 48-pin Stacked TSOP (CPL version) (Pb-free)
Q MLC 2 2
R MLC 2 2 Generation (M29 only)/Feature Set
T MLC 4 2 A = 1st set of device features
U MLC 4 2 B = 2nd set of device features (rev only if different than 1st set)
V MLC 4 + 4 2 + 2 C = 3rd set of device features (rev only if different)
W MLC 8 4 D = 4th set of device features (rev only if different)
Y MLC 8 4 etc.
Operating Voltage Range
A = 3.3V (2.70–3.60V), VccQ 3.3V (2.70–3.60V)
B = 1.8V (1.70–1.95V)
C = 3.3V (2.70–3.60V), VccQ 1.8V (1.70–1.95V)
*Contact Micron for help differentiating between standard and next-generation NAND offerings.

 

搜了下东芝的好像比较少有介绍,就找到一个表,贴上

型号

结构

页结构

块结构

工作电压(V)

温度

 速度

(nS)

封装

生产状态

注释

2Gb

TH58NVG1S3AFT05

256M x 8

2112B

128KB

2.7 ~ 3.6

C,I

50

48TSOP-I

量产

 

1Gb

TH58100FT

128M x 8

528B  

16KB

2.7 ~ 3.6

C,I

50

48TSOP-I

量产

-

TH58DVG02A1FT00

TC58NVG0S3FT05

2112B

128KB

C

512Mb

TC58512FT

64M x 8

528B

16KB

2.7 ~ 3.6

C,I

50

48TSOP-I

量产

-

TC58DVM92A1FT00

-

256Mb

TC58256AFT

32M x 8

528B

16KB

2.7 ~ 3.6

C,I

50

48TSOP-I

 

 

TC582562AXB

56TFBGA  

TC58DVM82A1FT00

48TSOP1

  

TC58DVM82A1XBJ1

56TFBGA 

 

K9F5616Q0C

16M x 16

264W

8KW

C 

48TSOP1

 

 

128Mb

TC58128AFT

16M x 8

528B

16KB

2.7 ~ 3.6

C,I

50

48TSOP-I

 

 

TC58DVM72A1FT00

 

TC58DVM72F1FT00

8M x 16

264W

8K W

2.7 ~ 3.6

 

 

 

 

64Mb

TC58V64BFT

8M x 8

528B

8KB

1.65 ~ 1.95

C

50

44TSOP-II

量产

 

TC58V64BFTI

2.7 ~ 3.6

I

[Note]

1.Operating Temperature(Celsius);  C:  Commercial(0°C~70°C),  I:  Industrial(-40°C~85°C)

2.To get pinout and package

 

本文内容由网友自发贡献,版权归原作者所有,本站不承担相应法律责任。如您发现有涉嫌抄袭侵权的内容,请联系:hwhale#tublm.com(使用前将#替换为@)

NAND FLASH命名规则 的相关文章

随机推荐

  • 解决Win7的一个毛病——睡眠失效(只关闭显示器,不关主机)

    1 按下windows徽标键 xff0c 输入regedit xff0c 进入注册表 xff1b 2 进入注册表的HKEY LOCAL MACHINE SYSTEM CurrentControlSet Control Session Man
  • 【视频】海康摄像头、NVR网络协议简介

    目录 郭老二博文之 图像视频汇总 1 软硬件整体架构 2 涉及的网络协议 3 协议简介 3 1 海康私有协议 设备发现SADP 进行设备的发现 激活 修改网络参数 忘记密码等 SDK 4200 系统平台的接入前端设备 协议不对外开放 但对外
  • 十分钟读懂游戏研发、发行、渠道那些事儿

    国庆在家写了7天东西 xff0c 实在是累得够呛 我重新梳理了一下以前做过的事儿 xff0c 正好把去年年初发到腾讯GAD的文章拿过来做个修改补充 xff0c 算是再做个总结吧 这篇文章主要是介绍游戏行业的上下游产业链有哪些玩家 xff0c
  • pomelo源码解析--新建项目(cli工具: pomelo)

    pomelo怎么新建项目 官方文档 1 安装pomelo 2 新建项目HelloWorld 我简单整理了下创建新项目关键步骤 xff1a 安装pomelo 方式一 xff1a npm install pomelo g 方式二 xff1a g
  • pomelo源码解析--启动项目(pomelo start)

    我们知道启动pomelo服务器是命令pomelo start xff0c 那执行pomelo start到底都做了些什么 xff1f 服务器之间是怎么连接的 xff1f 客户端是怎么给服务器发消息的 xff1f 下面我们通过源码一步步来展开
  • 博客迁移 https://cxx001.gitee.io

    博客新地址 xff1a https cxx001 gitee io
  • OpenGL--粒子系统

    理论基础 1 xff0c 粒子系统的基本思想是用许多形状简单且赋予生命的微小粒子作为基本元素来表示物体 一般由点或很小的多边形通过纹理贴图表示 xff0c 侧重于物体的总体形态和特征的动态变化 把物体定义为许多不规则 xff0c 随机分布的
  • Cocos2dx-- 聊天系统之富文本(RichText)与字体对齐

    前言 游戏开发中我们一般都会有聊天系统 xff0c 我们可以同时或单独发文字 xff0c 图片 xff0c 表情 xff0c 超链接等信息的文本即称为富文本 如下图所示 xff1a 我使用的是cocos 3 4引擎版本里的RichText富
  • OpenGL--天空盒

    理论基础 1 xff0c 目前虚拟场景中天空建模常用的方法有天空顶 SkyDome 半球形 和天空盒 SkyBox 长方体 两种方法 其本质都是摄像机处在一个盒子中间 xff0c 这个盒子通过纹理贴图形成的虚拟世界场景 其中天空盒绘制技术非
  • OpenGL--使用Shader

    创建Shader 关于在OpenGL中怎么创建Shader这个在很早我博客中就有过详细介绍了 这里全当复习 xff0c 温故而知新 xff5e 在OpenGL中 xff0c 存在Program和Shader两个概念 xff0c Progra
  • 轻松学习CAN总线系列---3.CAN数据遵循的格式

    CAN帧 帧类型数据帧远程帧寻址CRC和应答位填充 帧类型 数据帧 xff08 Data frame xff09 为传输用户数据 xff0c ISO 11898 1定义了数据帧 数据帧可以传输的最大有效负载为八个字节 xff0c 即数据场
  • 无法解析的外部符号 "public: virtual struct CRuntimeClass

    无法解析的外部符号 34 public virtual struct CRuntimeClass thiscall CMessageBox GetRuntimeClass void const 34 以下原因是会引起上述错误的 xff1a
  • Qt控件美化 用好CSS/QSS可视化工具

    一 CSS概念 级联样式表 CSS 包含应用于网页中的元素的样式规则 CSS 样式定义元素的显示方式以及元素在页中的放置位置 可以创建一个通用规则 xff0c 只要 Web 浏览器遇到一个元素实例 xff0c 或遇到一个分配给某个特定样式类
  • c/c++中的struct和class的区别

    主要有两种情况 xff1a 1 C语言中的struct和c 43 43 中的class区别 2 c 43 43 中的struct和c 43 43 中的class的区别 下面分别介绍 xff1a 1 C语言中的struct和c 43 43 中
  • Linux应用层对串口的使用操作

    在Linux中串口作为字符设备 xff0c 设备节点在 dev 目录下 xff0c 使用普通的open xff0c close xff0c write和read等系统调用即可使用 这其中会涉及到一些串口的基本属性的设置 xff0c 如 波特
  • 给定两个字符串str1和str2,查找str2在str1中出现的位置

    给定string str1和string str2 xff0c 编写一个库函数 xff0c 返回str2在str1中的位置 如 xff1a str1为 34 ABCDLANCEXYZ 34 xff0c str2为 34 LANCE 34 x
  • 中国交通标志检测数据集

    版权声明 xff1a 本文为转发问 xff0c 原文见博客 https blog csdn net dong ma article details 84339007 中国交通标志检测数据集 xff08 CCTSDB xff09 来源于 A
  • CentOS 修改ls目录的颜色

    修改ls目录的颜色 linux系统默认目录颜色是蓝色的 xff0c 在黑背景下看不清楚 xff0c 可以通过以下2种方法修改ls查看的颜色 bash profile文件在用的根目录下 xff0c ls al可以看到 方法一 xff1a 1
  • Tiny210(S5PV210) U-BOOT(六)----DDR内存配置

    上次讲完了Nand Flash的低级初始化 xff0c 然后Nand Flash的操作主要是在board init f nand xff0c 中 xff0c 涉及到将代码从Nand Flash中copy到DDR中 xff0c 这个放到后面实
  • NAND FLASH命名规则

    基于网络的一个修订版 三星的pure nandflash xff08 就是不带其他模块只是nandflash存储芯片 xff09 的命名规则如下 xff1a 1 Memory K 2 NANDFlash 9 3 Small Classifi